Difference between revisions of "Tasking Event-B Overview"

From Event-B
Jump to navigationJump to search
imported>Andy
imported>Andy
Line 98: Line 98:
 
*** A local-only event - the event only contains local updates, which are expanded to update actions in the implementation. In this case guards not permitted in the event.
 
*** A local-only event - the event only contains local updates, which are expanded to update actions in the implementation. In this case guards not permitted in the event.
 
*** A synchronizing event - local updates are expanded to become update actions in the implementation, remote updates are performed by subroutine call. Guards in the remote event may block; in Ada this is implemented as an entry barrier, and in C can be implemented using a pthread condition variable.
 
*** A synchronizing event - local updates are expanded to become update actions in the implementation, remote updates are performed by subroutine call. Guards in the remote event may block; in Ada this is implemented as an entry barrier, and in C can be implemented using a pthread condition variable.
** Sensing - Identifies an event that maps to a read from the environment. If the environment is simulated, i.e. without address variables, then the sensing event has an update action that models assignment of a return value from a subroutine call. If the event has addressed variables associated with its event parameters, then they map to direct reads from memory mapped variables in the generated code.
+
** Sensing annotation - This annotation is added to an event in the EMF tree. It identifies an event as one that maps to a read, from the environment. If the environment is simulated, i.e. without address variables, then the sensing event has an update action that models assignment of a return value from a subroutine call. If the event has addressed variables associated with its event parameters, then they map to direct reads from memory mapped variables in the generated code.
** Actuating - Identifies an event that maps to a write to the environment. If the environment is simulated without address variables then the actuating event has no update action. If a sensing event has addressed variables associated with its parameters then they map to direct writes to memory mapped variables in the generated code.  
+
** Actuating - This annotation is added to an event in the EMF tree. It identifies an event as one that maps to a write, to some variable in the environment. If the environment is simulated, without address variables, then the actuating event has no update action. If a sensing event has addressed variables associated with its parameters then they map to direct writes, to memory mapped variables in the generated code.  
  
 
Sensing (and actuating) events make use of synchronization. The sensing/actuating synchronizations only occur between AutoTasks and Environ machines. The data exchange, in sensing and actuating events, is modelled by the event parameters, and the result from the decomposition step. Shared machine events are mapped to subroutine declarations, and their parameters are always implemented as formal parameters. Formal parameters are place-holders in a subroutine; they are replaced by the actual parameters at run-time. To assist the code generator, we automatically identify the parameter direction during translation. We identify them as either in or out parameters.  
 
Sensing (and actuating) events make use of synchronization. The sensing/actuating synchronizations only occur between AutoTasks and Environ machines. The data exchange, in sensing and actuating events, is modelled by the event parameters, and the result from the decomposition step. Shared machine events are mapped to subroutine declarations, and their parameters are always implemented as formal parameters. Formal parameters are place-holders in a subroutine; they are replaced by the actual parameters at run-time. To assist the code generator, we automatically identify the parameter direction during translation. We identify them as either in or out parameters.  

Revision as of 16:13, 28 November 2011

Tasking Event-B

Tasking Event-B can be viewed as an extension of the existing Event-B language. We use the existing approaches of refinement and decomposition to structure a project that is suitable for a Tasking Development. During the modelling phase parameters are introduced to facilitate decomposition. As a result of the decomposition process, parameters become part of the interface that enables event synchronization. We make use of this interface and add information (see #Implementing Events) to facilitate code generation. The tasking extension consists of the constructs in the following table.

Construct Options
Machine Type DeclaredTask, AutoTask, SharedMachine, Environ
Control Sequence, Loop, Branch, Event, Output
Task Type Periodic(n), Triggered, Repeating, OneShot
Priority -
Event Role Actuating, Sensing
Addressed Variable Address, Base

Tasking Machines

The following constructs relate to Tasking and Environ Machines, and provide implementation details. Timing of periodic tasks is not modelled formally. Tasking and Environ Machines model Ada tasks, so they can be implemented easily in Ada; in C using the pthread library, or in Java using threads.

  • Tasking Machines may be one of the following types:
    • AutoTasks - Anonymous Tasks running from start-up.
    • Declared tasks - (Not currently used) A task template relating to an Ada tasktype declaration.

Auto Tasks are tasks that will be declared and defined in the Main procedure of the implementation. The effect of this is that the Auto Tasks are created when the program first loads, and then activated (made ready to run) before the Main procedure body runs.

  • Tasking and Environ Machines options are:
    • TaskType - Defines the scheduling, cycle and lifetime of a task. i.e. one-shot periodic or triggered. The period of a task is specified in milliseconds.
    • Priority - An integer value is supplied, the task with the highest value priority takes precedence when being scheduled. The default priority is 5.

Shared Machines

A Shared Machine models a protected resource, such as a monitor. It may be implemented in Ada as a Protected Object, in C using mutex locking, or in Java as a monitor.

  • A Shared Machine is identified using the Shared Machine annotation.

The Environ Machine

An Environ machine is a model of the environment. It can be used to generate code for use in a simulation, or be discarded in the case that a simulated environment is not required.

  • An Environ Machine is identified using the Environ Machine annotation.

Control of Program Flow

At the implementation stage we need to think about controlling the flow of execution; and where interaction with the environment is concerned, how events should be implemented. The following section describes the constructs that we have introduced to facilitate this.

Control Constructs

Each Tasking Machine has a task body which contains the flow control (algorithmic constructs).

  • We have the following constructs available in the Tasking Machine body:
    • Sequence - for imposing an order on events.
    • Branch - choice between a number of mutually exclusive events.
    • Loop - event repetition while it's guard remains true.
    • Event - a wrapper for the Event-B element (soon to be redundant).
    • Text Output - writes textual output to the screen.

The syntax for task bodies, as used in the Rose TaskBody editor, is as follows:


Syntax.png


The String will be an event name, a variable name, or a text fragment to be output to the screen. The concrete syntax is shown in bold red font. '*' indicates 0 or more; [] indicates 0 or 1.

Event Translation

When an event, used in the task body, is translated to an implementation its translation depends on where it is used in the task body. The mappings are relatively simple for branch, loop, and sequence; but, in addition to the parent construct, the Event translation depends on whether it is part of a synchronization. Obviously the simplest translation is when no synchronization is involved. The translator checks the composed machine to see if the event is paired in a combined event. We say that events is a Tasking machine are local, and that events in a Shared or Environ machine, are remote. If there is no synchronization, then the actions of the local event are expanded in-line in the subroutine body.

NOTE: As a result of the decomposition process, the tool can produce a remote event, without a corresponding local event. A local event, with no guards and skip action, must be added manually to the tasking machine, and composed machine in order to facilitate code generation. This relates to an implementation with a subroutine call, where there are no parameters passed, and no local updates i.e. remote updates only. The addition of the 'dummy' event will be automated in a pre-processing step in the near future. It is not necessary to have a dummy remote event if a remote event does not exist.

Synchronization

Synchronization between local events (in AutoTasks) and remote events (in shared/Environ Machines) is determined using the composed machine. To use an event simply enter its name in the TaskBody editor. The translator will in-line any local actions, and add a call to perform remote updates, and obtain remote data.

Synchronization corresponds to:

  • a subroutine call from task to shared machine, or,
  • sensing or actuating of environment variables.

In the case of a subroutine call the subroutine is an atomic (with respect to an external viewer) update to state. The updates in the protected resource are implemented by a procedure call to a protected object, and tasks do not share state. The synchronization construct also provides the means to specify parameter passing, both in and out of the task.

In the case of a sensing or actuating event, the updates of the action correspond to reads of monitored variables, and writes to controlled variables of the environment.

Implementing Events

An event's role in the implementation is identified by its parent in the task body. A description follows, in general terms, of the possible implementations of an event.

Note: An event can be to referred only once in a task body specification. Of course, shared events (in Shared machines) can be re-used, but this is done through synchronization. The task body only refers to local events

  • Event roles in implementation:
    • Branching: an event is split in the implementation; guards are mapped to branch conditions, and actions are mapped to the branch body. If the branch synchronizes with a Shared machine's event then this is mapped to a procedure call.
    • Looping: as in branching, the event is split; the guard maps to the loop condition, and actions to to loop body. If the event synchronizes with a Shared Machine event then it is mapped to a procedure call.
    • Event: if the event is not contained in a branch or loop then it is one of the following:
      • A local-only event - the event only contains local updates, which are expanded to update actions in the implementation. In this case guards not permitted in the event.
      • A synchronizing event - local updates are expanded to become update actions in the implementation, remote updates are performed by subroutine call. Guards in the remote event may block; in Ada this is implemented as an entry barrier, and in C can be implemented using a pthread condition variable.
    • Sensing annotation - This annotation is added to an event in the EMF tree. It identifies an event as one that maps to a read, from the environment. If the environment is simulated, i.e. without address variables, then the sensing event has an update action that models assignment of a return value from a subroutine call. If the event has addressed variables associated with its event parameters, then they map to direct reads from memory mapped variables in the generated code.
    • Actuating - This annotation is added to an event in the EMF tree. It identifies an event as one that maps to a write, to some variable in the environment. If the environment is simulated, without address variables, then the actuating event has no update action. If a sensing event has addressed variables associated with its parameters then they map to direct writes, to memory mapped variables in the generated code.

Sensing (and actuating) events make use of synchronization. The sensing/actuating synchronizations only occur between AutoTasks and Environ machines. The data exchange, in sensing and actuating events, is modelled by the event parameters, and the result from the decomposition step. Shared machine events are mapped to subroutine declarations, and their parameters are always implemented as formal parameters. Formal parameters are place-holders in a subroutine; they are replaced by the actual parameters at run-time. To assist the code generator, we automatically identify the parameter direction during translation. We identify them as either in or out parameters.

Addressed Variables

When sensing monitored variables, or actuating controlled variables in the environment, we may wish to use explicit memory addresses for use in the final implementation, or perhaps in the environment simulation too. We can link a task's event parameters, and an Environ machines variables, with specific addresses and use these in the generated code.

References