Development of a Heating Controller System: Difference between revisions
imported>Reza |
imported>Reza |
||
(65 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{TOCright}} | {{TOCright}} | ||
==Introduction== | ==Introduction== | ||
This section describes an Event-B development of a simple heating controller. This is | This section describes an Event-B development of a simple heating controller. This is the first case study to cover the entire development process; starting from a system specification and ending up with implementable Ada code. The development process starts with an abstract specification followed by two successive refinements, we then decompose the model into two separate sub-models representing the environment and the rest of the system. The refinement process continues after the first decomposition in order to arrive at a concrete level suitable for implementation. This allows us to derive the appropriate tasking structure that is needed by the code generation plug-in. The second decomposition gives rise to a number of tasking machines, plus a specific type of machine for representing protected shared data. This protected shared data facilitating communications between tasking machines. Then we illustrate how, using the code generation plug-in, a concurrent Ada implementation is generated. The overall aim of this case study is to put in practice the recommended methodological aspects of Event-B, particularly those aspects of modelling concerned with decomposition and code generation. | ||
==System Architecture== | ==System Architecture== | ||
In | <div id="fig:System Architecture"> | ||
The controller uses two '''Temperature Sensors''' to poll the environment temperature. The average of the values read from these two sensors is calculated and displayed by the controller on the '''Current Temperature Display'''. If the current temperature is ''lower'' than the target temperature, the controller will turn on the heater source using '''Heat Source Switch''', otherwise this switch will be turned off by the controller. The status of the heater itself also will be monitored through the '''Heater Sensor'''. If due to some faults the heater is not working properly, the controller will activate either of '''Over-temperature''' or '''No-heat | <br/> | ||
[[Image:HeatingController1.jpg|center||caption text]] | |||
<center>'''Figure 1''': System Architecture</center> | |||
<br/> | |||
</div> | |||
In the [[:Image:HeatingController1.jpg|System Architecture]] diagram an overview of the '''Heating Controller''' and its related components are presented. The controller in the middle of the diagram communicates with the components in the environment using input and output parameters. At the top there are two buttons that allow the user to increase/decrease '''Target Temperature'''. The target temperature periodically will be sent by the controller to the related display to be shown to the outside world. | |||
The controller uses two '''Temperature Sensors''' to poll the environment temperature. The average of the values read from these two sensors is calculated and displayed by the controller on the '''Current Temperature Display'''. If the current temperature is ''lower'' than the target temperature, the controller will turn on the heater source using '''Heat Source Switch''', otherwise this switch will be turned off by the controller. The status of the heater itself also will be monitored through the '''Heater Sensor'''. If due to some faults the heater is not working properly, the controller will activate either of '''Over-temperature Alarm''' or '''No-heat Alarm''' | |||
---- | ---- | ||
'''Main | '''Main Functionality of the System''' | ||
* | * Provide an interface to adjust the Target Temperature | ||
* | * Display the Target Temperature | ||
* | * Sense the Current Temperature | ||
* | * Display the Current Temperature | ||
* Power on/off Heater | * Power on/off the Heater | ||
* | * Sense the Heater Status | ||
* | * Activate/Deactivate the No-Heat Alarm | ||
* | * Activate/Deactivate Over-Heat Alarm | ||
{| border=" | {|align="center" border="2" cellpadding="5" cellspacing="1" | ||
|+An Overview of the Main Variables | |+ '''An Overview of the Main Variables''' | ||
!Interfaces | !Interfaces | ||
!Types | !Types | ||
!Definitions | !Definitions | ||
|- | |||
|Increase/Decrease Target Temp. Buttons | |||
|Boolean | |||
|True when buttons are pressed | |||
|- | |- | ||
|Temperature Sensors | |Temperature Sensors | ||
Line 32: | Line 43: | ||
|Temperature in degrees Celsius | |Temperature in degrees Celsius | ||
|- | |- | ||
|Heater | |Heater Sensor | ||
|Boolean | |Boolean | ||
|True when heater is at working temperature, False otherwise | |True when heater is at working temperature, False otherwise | ||
|- | |||
|Heat Source Switch | |||
|Boolean | |||
|True when activated, False otherwise | |||
|- | |||
|No-heat Alarm | |||
|Boolean | |||
|True when activated, False otherwise | |||
|- | |||
|Over-temperature Alarm | |||
|Boolean | |||
|True when activated, False otherwise | |||
|- | |||
|Current temperature | |||
|Integer | |||
|Average temperature value in degrees Celsius | |||
|- | |||
|Target temperature | |||
|Integer | |||
|Target temperature value in degrees Celsius | |||
|} | |} | ||
==An Overview of the System Development== | |||
Before discussing Event-B models the Heater Controller in more detail, it is useful to provide an overview of the development approach. In this section we demonstrate this with a diagram. Starting from the top level of the diagram, it shows the most abstract model of the system or as it know as the system specification. In this stage we have specified the main system’s functionality. This includes events for modelling increase/decrease target temperature, polling the environment temperature using two available sensors, calculating current temperature, turning on/off the heat source, and finally activating or deactivating two different alarms should it deemed to be necessary by the controller. Events in this stage are deliberately simple to achieve maximum comprehensibility. Events ordering and iteration is introduced in the later stages. | |||
[[Image:development.jpg|center]] | |||
In the first refinement level we introduce sensing and actuation which are considered as design steps. Here sensing involves polling the state of increase/decrease buttons, temperature sensors, and the heater sensor. Actuation concerns the update of target and current temperature displays with latest values, as well as sending outcomes of controller decisions to appropriate actuators such as heat on/off, and various alarms. | |||
==System Decomposition== | |||
As illustrated in the system development diagram we decompose our model in two stages. In the first stage we separate the controller, the part of the system that should be implemented, from its surrounding environment. The second stage of decomposition is concerned with the tasking structure of the implementable system. This an open issue for the designer and it is based on his/her personal choice as well as targeted platform and possible options available to him/her. | |||
===First level decomposition=== | |||
In Event-B usually we start modelling with specifying the whole system as a closed system. This includes the system that we are intending to develop plus its surrounding environment. Therefore when our model of the system becomes big and complex it is reasonable to separate the actual system from its environment. Hence in the first stage of decomposition we decompose our model to two parts, namely the controller and the environment. | |||
[[Image:Decomp1.jpg|center]] | |||
The environment machine includes all the physical parts that the system we are intended to build is interacting with. These include buttons, sensors, actuators and their related behaviours. In addition to these the environment machine has to include the synchronisation mechanism between the physical elements and our system. | |||
===Second level decomposition=== | |||
In this stage we decompose the controller to three different tasks which interacting with each other through a shared object. This structure is presented in the following figure. Note that tasks still are able to communicate with the environment directly. In practice the number of the tasks and the way that we distribute different events over these tasks are determined by various factors. Other properties of tasks, such as their priorities, whether they are periodic or not, and the length of each periodic task in millisecond are defined later in the tasking development stage. | |||
[[Image:Decomp2.jpg|center]] | |||
=== The Tasking Event-B Tutorial === | |||
Now that we have fully developed Event-B models that encompass basic structures for tasks we can move to the next stage. This is to generate an executable Ada code for the system using the code generation plug-in. This is the first time that this plug-in explored extensively; therefore we present the next stage in the form of a tutorial. | |||
The Tasking Event-B tutorial starts [[Tasking Event-B Tutorial|here]]. Also a link to an archive file, which includes the complete development, can be found on this page. |
Latest revision as of 10:06, 12 May 2011
Introduction
This section describes an Event-B development of a simple heating controller. This is the first case study to cover the entire development process; starting from a system specification and ending up with implementable Ada code. The development process starts with an abstract specification followed by two successive refinements, we then decompose the model into two separate sub-models representing the environment and the rest of the system. The refinement process continues after the first decomposition in order to arrive at a concrete level suitable for implementation. This allows us to derive the appropriate tasking structure that is needed by the code generation plug-in. The second decomposition gives rise to a number of tasking machines, plus a specific type of machine for representing protected shared data. This protected shared data facilitating communications between tasking machines. Then we illustrate how, using the code generation plug-in, a concurrent Ada implementation is generated. The overall aim of this case study is to put in practice the recommended methodological aspects of Event-B, particularly those aspects of modelling concerned with decomposition and code generation.
System Architecture
In the System Architecture diagram an overview of the Heating Controller and its related components are presented. The controller in the middle of the diagram communicates with the components in the environment using input and output parameters. At the top there are two buttons that allow the user to increase/decrease Target Temperature. The target temperature periodically will be sent by the controller to the related display to be shown to the outside world.
The controller uses two Temperature Sensors to poll the environment temperature. The average of the values read from these two sensors is calculated and displayed by the controller on the Current Temperature Display. If the current temperature is lower than the target temperature, the controller will turn on the heater source using Heat Source Switch, otherwise this switch will be turned off by the controller. The status of the heater itself also will be monitored through the Heater Sensor. If due to some faults the heater is not working properly, the controller will activate either of Over-temperature Alarm or No-heat Alarm
Main Functionality of the System
- Provide an interface to adjust the Target Temperature
- Display the Target Temperature
- Sense the Current Temperature
- Display the Current Temperature
- Power on/off the Heater
- Sense the Heater Status
- Activate/Deactivate the No-Heat Alarm
- Activate/Deactivate Over-Heat Alarm
Interfaces | Types | Definitions |
---|---|---|
Increase/Decrease Target Temp. Buttons | Boolean | True when buttons are pressed |
Temperature Sensors | Integer | Temperature in degrees Celsius |
Heater Sensor | Boolean | True when heater is at working temperature, False otherwise |
Heat Source Switch | Boolean | True when activated, False otherwise |
No-heat Alarm | Boolean | True when activated, False otherwise |
Over-temperature Alarm | Boolean | True when activated, False otherwise |
Current temperature | Integer | Average temperature value in degrees Celsius |
Target temperature | Integer | Target temperature value in degrees Celsius |
An Overview of the System Development
Before discussing Event-B models the Heater Controller in more detail, it is useful to provide an overview of the development approach. In this section we demonstrate this with a diagram. Starting from the top level of the diagram, it shows the most abstract model of the system or as it know as the system specification. In this stage we have specified the main system’s functionality. This includes events for modelling increase/decrease target temperature, polling the environment temperature using two available sensors, calculating current temperature, turning on/off the heat source, and finally activating or deactivating two different alarms should it deemed to be necessary by the controller. Events in this stage are deliberately simple to achieve maximum comprehensibility. Events ordering and iteration is introduced in the later stages.
In the first refinement level we introduce sensing and actuation which are considered as design steps. Here sensing involves polling the state of increase/decrease buttons, temperature sensors, and the heater sensor. Actuation concerns the update of target and current temperature displays with latest values, as well as sending outcomes of controller decisions to appropriate actuators such as heat on/off, and various alarms.
System Decomposition
As illustrated in the system development diagram we decompose our model in two stages. In the first stage we separate the controller, the part of the system that should be implemented, from its surrounding environment. The second stage of decomposition is concerned with the tasking structure of the implementable system. This an open issue for the designer and it is based on his/her personal choice as well as targeted platform and possible options available to him/her.
First level decomposition
In Event-B usually we start modelling with specifying the whole system as a closed system. This includes the system that we are intending to develop plus its surrounding environment. Therefore when our model of the system becomes big and complex it is reasonable to separate the actual system from its environment. Hence in the first stage of decomposition we decompose our model to two parts, namely the controller and the environment.
The environment machine includes all the physical parts that the system we are intended to build is interacting with. These include buttons, sensors, actuators and their related behaviours. In addition to these the environment machine has to include the synchronisation mechanism between the physical elements and our system.
Second level decomposition
In this stage we decompose the controller to three different tasks which interacting with each other through a shared object. This structure is presented in the following figure. Note that tasks still are able to communicate with the environment directly. In practice the number of the tasks and the way that we distribute different events over these tasks are determined by various factors. Other properties of tasks, such as their priorities, whether they are periodic or not, and the length of each periodic task in millisecond are defined later in the tasking development stage.
The Tasking Event-B Tutorial
Now that we have fully developed Event-B models that encompass basic structures for tasks we can move to the next stage. This is to generate an executable Ada code for the system using the code generation plug-in. This is the first time that this plug-in explored extensively; therefore we present the next stage in the form of a tutorial.
The Tasking Event-B tutorial starts here. Also a link to an archive file, which includes the complete development, can be found on this page.